Hoshizaki FD-1001MAH(-C) 사용자 설명서

다운로드
페이지 44
1
5. Electrical Connection
 WARNING
1. Electrical connection must meet national, state, and local electrical code 
requirements. Failure to meet these code requirements could result in death, 
electric shock, serious injury, fire, or severe damage to equipment.
THE REMOTE CONDENSER UNIT MUST BE GROUNDED. Install a proper 
ground wire from the icemaker to the remote condenser unit. Use wire of 
an appropriate gage and outdoor rating. Failure to properly ground the unit 
could result in death or serious injury.
3. The remote condenser unit leads must be connected to the fan motor 
junction box leads on the icemaker. Use wire of an appropriate gage and 
outdoor rating. 
4. Do not connect the leads to an external power source. Do not connect the 
icemaker's fan motor junction box leads together. Do not allow the leads to 
contact the junction box walls.
5. To reduce the risk of electric shock, make all remote condenser unit 
connections before connecting the icemaker power supply.
6. On remote air-cooled model, the icemaker should have power for a minimum 
of 4 hours prior to startup to prevent compressor damage.
• Usually an electrical permit and services of a licensed electrician are required.
• The opening for the power supply connection is 7/8" DIA to fit a 1/" trade size conduit.
1) Remove the louver panel. See Fig. 9.
) Remove the junction box cover on the remote condenser unit. Remove the fan motor 
junction box cover on the icemaker.
3) Install a ground wire from the icemaker to the remote condenser unit. Use wire of an 
appropriate gage and outdoor rating. 
4) Connect the fan motor leads in the junction box of the remote condenser unit to the fan 
motor leads in the fan motor junction box of the icemaker. Use wire of an appropriate 
gage and outdoor rating.
5) Replace the junction box covers and the louver panel in their correct positions.
Fig. 9
Screws
Louver Panel
Junction Box 
Cover
Remote Condenser Unit
Icemaker
Screw
Fan Motor Junction 
Box Cover
Power Supply 
Junction Box Cover