2.7.2
MDIO Module Operational Overview
Peripheral Architecture
The MDIO module implements the 802.3 serial management interface to interrogate and control an
Ethernet PHY, using a shared two-wired bus. It separately performs autodetection and records the current
link status of up to 32 PHYs, polling all 32 MDIO addresses.
Application software uses the MDIO module to configure the autonegotiation parameters of the PHY
attached to the EMAC, retrieve the negotiation results, and configure required parameters in the EMAC.
In this device, the Ethernet PHY attached to the system can be directly controlled and queried. The Media
Independent Interface (MII) address of this PHY device is specified in one of the PHYADRMON bits in the
MDIO user PHY select register (USERPHYSELn). The MDIO module can be programmed to trigger a
CPU interrupt on a PHY link change event, by setting the LINKINTENB bit in USERPHYSELn. Reads and
writes to registers in this PHY device are performed using the MDIO user access register
(USERACCESSn).
The MDIO module powers-up in an idle state until specifically enabled by setting the ENABLE bit in the
MDIO control register (CONTROL). At this time, the MDIO clock divider and preamble mode selection are
also configured. The MDIO preamble is enabled by default, but can be disabled when the connected PHY
does not require it. Once the MDIO module is enabled, the MDIO interface state machine continuously
polls the PHY link status (by reading the generic status register) of all possible 32 PHY addresses and
records the results in the MDIO PHY alive status register (ALIVE) and MDIO PHY link status register
(LINK). The corresponding bit for the connected PHY (0-31) is set in ALIVE, if the PHY responded to the
read request. The corresponding bit is set in LINK, if the PHY responded and also is currently linked. In
addition, any PHY register read transactions initiated by the application software using USERACCESSn
causes ALIVE to be updated.
The USERPHYSELis used to track the link status of the connected PHY address. A change in the link
status of the PHY being monitored sets the appropriate bit in the MDIO link status change interrupt
registers (LINKINTRAW and LINKINTMASKED), if enabled by the LINKINTENB bit in USERPHYSELn.
While the MDIO module is enabled, the host issues a read or write transaction over the MII management
interface using the DATA, PHYADR, REGADR, and WRITE bits in USERACCESSn. When the application
sets the GO bit in USERACCESSn, the MDIO module begins the transaction without any further
intervention from the CPU. Upon completion, the MDIO module clears the GO bit and sets the
corresponding USERINTRAW bit (0 or 1) in the MDIO user command complete interrupt register
(USERINTRAW) corresponding to USERACCESSused. The corresponding USERINTMASKED bit (0 or
1) in the MDIO user command complete interrupt register (USERINTMASKED) may also be set,
depending on the mask setting configured in the MDIO user command complete interrupt mask set
register (USERINTMASKSET) and the MDIO user interrupt mask clear register (USERINTMASKCLEAR).
A round-robin arbitration scheme is used to schedule transactions that may be queued using both
USERACCESS0 and USERACCESS1. The application software must check the status of the GO bit in
USERACCESSbefore initiating a new transaction, to ensure that the previous transaction has
completed. The application software can use the ACK bit in USERACCESSto determine the status of a