Table 7: LCD Panel Menu Options for the EX8200 Switch (continued)
Description
Menu
The Maintenance menu has the following options:
SYSTEM HALT?—Choose one of the following:
Press
Enter
to halt the master SRE module in an EX8208 switch or to halt the master RE module in an
EX8216 switch. Press
Enter
again to confirm the halt.
In a base configuration switch, the master SRE or RE module will be gracefully halted but not powered
off. Press
Enter
on your management device or power cycle the switch to bring the switch back up.
In a redundant configuration, the backup SRE or RE module takes over mastership when the master SRE
or RE module is halted. To completely halt the switch, use the
request system halt other-routing-engine
CLI command to halt the backup SRE or RE module before halting the master SRE or RE module. Press
Enter
on your management device or power cycle the switch to bring the switch back up.
See “EX8208 Switch Configurations” on page 6 or EX8216 Switch Configurations for information on
configuration types.
Press
Menu
to go to the next option in the Maintenance menu.
SYSTEM REBOOT?—Choose one of the following:
Press
Enter
to reboot the master SRE or RE module. Press
Enter
again to confirm the reboot.
Press
Menu
to go to the next option in the Maintenance menu.
LOAD RESCUE?—Choose one of the following:
Press
Enter
to roll back the switch to the previous valid configuration. Press
Enter
again to confirm the
rollback.
Press
Menu
to go to the next option in the Maintenance menu.
FACTORY DEFAULT?—Choose one of the following:
Press
Enter
to restore the switch to the factory default configuration. Press
Enter
again to confirm the
restoration. The LCD flashes a success or failure message and returns to the Idle menu.
Press
Menu
to go to the next option in the Maintenance menu.
ENTER EZSETUP?—Choose one of the following:
Press
Enter
to launch EZSetup. Press
Enter
again to confirm the launch.
EZSetup configures DHCP and enables the J-Web user interface on the switch. The LCD flashes a success
or failure message for approximately 10 seconds and returns to the Idle menu.
Press
Menu
to go to the next option in the Maintenance menu.
NOTE: You can use the EZSetup option only if the switch is in the factory default configuration.
EXIT MAINT MENU?—Choose one of the following:
Press
Enter
to exit the Maintenance menu.
Press
Menu
to return to the SYSTEM HALT option.
If you do not want users to use Maintenance menu options, disable the entire menu or individual menu options.
See Configuring the LCD Panel on EX Series Switches (CLI Procedure).
Maintenance
You can view the information about the LCD panel in EX8200 switches by executing the
command
show chassis hardware
. It shows the version, part number, serial number, and
description of the LCD panel.