Juniper Networks EX8208 사용자 설명서

다운로드
페이지 338
Related Topics
Understanding Alarm Types and Severity Levels on EX Series Switches
Field-Replaceable Units in an EX8208 Switch
Field-replaceable units (FRUs) are switch components that you can replace at your site.
The switch uses these types of FRUs:
Hot-insertable and hot-removable—You can remove and replace these components
without powering off the switch or disrupting the switching function.
Hot-pluggable—You can remove and replace these components without powering off
the switch, but the switching function is interrupted until you replace the component.
Table 9 on page 23 lists the FRUs for the EX8208 switch and their types.
Table 9: FRUs in an EX8208 Switch
Type
FRU
Hot-insertable and hot-removable.
Power supplies
Hot-insertable and hot-removable.
Fan tray
Redundant configuration:
Master SRE module is hot-pluggable.
Backup SRE module is hot-insertable and hot-removable.
Base configuration:
Switch must be disabled before the SRE module is removed. See “Taking the SRE
Module Offline in an EX8208 Switch” on page 213
.
Switch Fabric and Routing Engine (SRE)
module
Redundant configuration:
SF module is hot-insertable and hot-removable.
Base configuration:
We recommend that you disable the switch before removing the SF module. See
“Taking the SF Module Offline in an EX8208 Switch” on page 216.
Switch Fabric (SF) module
Hot-insertable and hot-removable.
We recommend that you take the line cards offline before removing them. See
“Removing a Line Card from an EX8200 Switch” on page 218.
8-port SFP+ line card
40-port SFP+ line card
48-port SFP line card
48-port RJ-45 line card
Hot-insertable and hot-removable.
SFP and SFP+ transceivers
23
Copyright © 2010, Juniper Networks, Inc.
Chapter 2: Component Descriptions