Table 4: LCD Panel Menu Options in EX3200 and EX4200 Switches (continued)
Description
Menu
The Maintenance menu has the following options to configure and troubleshoot the switch:
SYSTEM HALT?—Select this option using the 
Enter
 button to halt the switch. Press the 
Enter
 button again
to confirm the halt. Press the 
Menu
 button to go to the next option in the Maintenance menu.
SYSTEM REBOOT?—Select this option using the 
Enter
 button to reboot the switch. Press the 
Enter
 button
again to confirm the reboot. Press the 
Menu
 button to go to the next option in the Maintenance menu.
LOAD RESCUE?—Select this option using the 
Enter
 button to roll back the switch to the rescue
configuration. Press the 
Enter
 button again to confirm the rollback. Press the 
Menu
 button to go to the
next option in the Maintenance menu.
REQUEST VC PORT?—Select this option using the 
Enter
 button to configure an uplink module port or an
EX4200-24F network port to be a Virtual Chassis port (VCP) or to delete a VCP from the switch
configuration (when you delete the VCP, the port is reset to an uplink module port or an EX4200-24F
network port).
For information on how to use the REQUEST VC PORT option, see Setting an Uplink Module Port or an
EX4200-24F Network Port as a Virtual Chassis Port Using the LCD Panel.
FACTORY DEFAULT?—Select this option using the 
Enter
 button to restore the switch to the factory default
configuration. Press the 
Enter
 button again to confirm the restoration. Press the 
Menu
 button to go to
the next option in the Maintenance menu.
ENTER EZSETUP?—Select this option using the 
Enter
 button to launch EZSetup. Press the 
Enter
 button
again to confirm the launch. Press the 
Menu
 button to go to the next option in the Maintenance menu.
You can use the ENTER EZSETUP option only if the switch is in the factory default configuration.
EXIT MAINT MENU?—Select this option to exit the Maintenance menu.
MAINT
(Maintenance
Menu)
Related Topics
Field-Replaceable Units in EX3200 and EX4200 Switches
Field-replaceable units (FRUs) are components that you can replace at your site. The
field-replaceable units (FRUs) in EX3200 and EX4200 switches are:
Power supply
Fan tray
Uplink module
SFP transceiver
16
Field-Replaceable Units in EX3200 and EX4200 Switches
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches