  Chapter 4.  Installation    
|
    
21
GS752TXS Smart Switch Hardware Installation Guide 
Step 1: Preparing the Site
Before you install the switch, ensure the operating environment meets the site requirements in 
the following table.
Step 2: Installing the Switch
The GS752TXS Smart Switch can be used on a flat surface or mounted in a standard 
network equipment rack.
Installing the Switch on a Flat Surface
The switch ships with four self-adhesive rubber footpads. Stick one rubber footpad on each of 
the four concave spaces on the bottom of the switch. The rubber footpads cushion the switch 
against shock and vibrations. They also provide ventilation space between stacked switches.
Installing the Switch in a Rack
To install the switch in a rack, you need the 19-inch rackmount kit supplied with the switch.
1. 
Attach the supplied mounting brackets to the side of the switch. 
2. 
Insert the screws provided in the rackmount kit through each bracket and into the bracket 
mounting holes in the switch. 
3. 
Tighten the screws with a #1 Phillips screwdriver to secure each bracket. 
Characteristics
Requirements
Mounting
•  Desktop installations - Provide a flat table or shelf surface.
• Rackmount installations - Use a 19-inch (48.3-centimeter) EIA standard equipment rack that 
is grounded and physically secure. The rackmount kit supplied with the switch is also required. 
Access
Locate the switch in a position that allows you to access the front-panel RJ-45 ports, view the 
front-panel LEDs, and access the power connector.
Power source
Provide a power connection cord. Power specifications for the switch are shown in 
Ensure the AC outlet is not controlled by a wall switch, which can accidentally turn off power to 
the outlet and the switch.
Environmental
• Temperature - Install the switch in a dry area, with ambient temperature between 0 and 40ºC 
(32ºF and 104ºF). Keep the switch away from heat sources such as direct sunlight, warm air 
exhausts, hot-air vents, and heaters.
• Operating humidity - The installation location should have a maximum relative humidity of 
90%, non-condensing.
•  Ventilation - Do not restrict airflow by covering or obstructing air inlets on the sides of the 
switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. Be sure there is 
adequate airflow in the room or wiring closet where the switch is installed.
• Operating conditions - Keep the switch at least 6 ft. (1.83 meters) away from nearest source 
of electromagnetic noise, such as a photocopy machine.