Siemens SCALANCE X-200 사용자 설명서

다운로드
페이지 296
Configuration / diagnostics using remote mechanisms 
 
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) 
 
SCALANCE X-200 
228
 
Operating Instructions, 12/2011, A5E00349864-19 
Loop Detection Control 
The following settings are available: 
●  "Loop Detection enabled" check box 
Here you can enable loop detection for this switch. If loop detection is disabled, loop 
detection frames of other devices are forwarded. 
●  "Rx-Threshold (All Ports)" input box 
Here, you can enter the number of received frames after which a loop is assumed. If a 
port-specific setting was made "Variant" is displayed. 
●  "Remote Loop Reaction (All Ports)" drop-down list 
Here you can specify for all ports whether a port is activated or deactivated if a remote 
loop is detected. If a port-specific setting was made "Variant" is displayed. 
●  "Local Loop Reaction (All Ports)" drop-down list 
Here you can specify for all ports whether a port is activated or deactivated if a local loop 
is detected. If a port-specific setting was made "Variant" is displayed. 
Loop Detection Port Control 
Meaning of the column entries: 
●  "Port" display box 
The relevant port is listed here. 
●  "Setting" drop-down list 
In this area, you define the behavior of the port. You can choose from the following 
options: 
–  "Sender" 
If this option is set, loop detection frames are sent and forwarded. 
–  "Forwarder" 
If this option is set, loop detection frames of other devices are forwarded. 
–  "Blocked" 
If you select this option, the forwarding of loop detection frames is blocked. 
●  "Rx-Threshold" input box 
Here, you can specify the number of received frames after which a loop is assumed. 
●  "Remote Loop Reaction" drop-down list 
Here, you can activate or deactivate a port if a remote loop is detected. 
●  "Local Loop Reaction" drop-down list 
Here, you can activate or deactivate a port if a local loop is detected. 
●  "State" display box 
Shows the status of the loop detection for the corresponding port.