Indicates the number of collisions that have occurred. 
 
 
Note 
X-200IRT IE switches work in the cut-through mode. 
If a frame is received with a bad checksum, the forwarding of the frame is aborted 
prematurely and the frame is therefore shortened. The counter for CRC errors is 
incremented. 
If the frame involved is a frame with a length of 64 bytes, the counter for undersize errors is 
also incremented due to the shortening of the frame 
 
Syntax of the Command Line Interface 
Table 6- 35  Statistic Packet Error - CLI\INFORM> 
Command 
Description 
Comment 
errors 
Displays statistical information 
on received errors.