••••  Installation 
2000585-001 
DataNET Hub Signal Equalizer Board, 
Continued
 
 
Selec-
tion 
 
Ratio 
DB 
loss 
 
SW1 
 
SW2 
 
SW3 
 
 
 
1 2  3  1 2  3 1 2  3 
on on  off  on on  off on on  off 
1.5 
3.5  off off  on  on on  off on on  off 
2.2 
6.8  on on  off  off off  on on on  off 
9.4  off off  on  off off  on on on  off 
3.5 
11  on on  off  on on  off off off  on 
4.1 
12.3 off off  on  on on  off off off  on 
4.8 
13.6 on on  off  off off  on off off  on 
5.2 
14.3 off off  on  off off  on off off  on 
 
Calculation One: 
Assume connections to Port 1 and Port 2 only. 
Port 1 cable = 1000 ft. in length 
Port 2 cable = 4000 ft. in length (3000 ft. difference) 
Result:  
Based on Table 2-2 data, 
Port 1 requires compensation for 3000 ft. Selection 4 (2500-3500 feet) 
Port 2 requires no compensation. Selection 1 (0 dB loss) 
Calculation Two: 
Assume connections to Port 1, Port 2, and Port 6 
Port 6 cable = 5000 feet 
Port 1 cable = 1000 ft. (5000 ft. - 1000 ft. = 4000 ft. difference) 
Port 2 cable = 4000 ft. (5000 ft. - 4000 ft. = 1000 ft. difference) 
Result: 
Based on Table 2-2 data, 
Port 6 requires no compensation. Selection 1 (0 dB loss) 
Port 1 requires compensation for 4000 ft. Selection 6 (3500 - 4500) 
Port 2 requires compensation for 1000 ft. Selection 2 (500 - 1500 ft.) 
Note that the lengths of Port 1 and Port 2 cable are the same as in Cal-
culation One, however, with the addition of a longer length for Port 6, 
new settings are required for Port 1 and Port 2. 
 
Table 2-2. Recommended 
Equalizer Board Settings 
Sample Calculations