Siemens DataNET Hub (DNH) 사용자 설명서

다운로드
페이지 97
34  
••••  Installation 
2000585-001 
DataNET Hub Signal Equalizer Board  
This section sets the switches on the DataNET Hub Signal Equalizer 
board. This board is used to equalize the signal amplitude when varying 
lengths of copper cable are connected to multiple downlink ports on the 
DNH. 
Typically the smallest signal on any DNH port is found on the port with 
the longest copper cable. Since, Signal Equalizer boards are placed on 
ports with signal levels greater than 3 dB the port with the longest cable 
does not require a Signal Equalizer board. 
 
This procedure determines the attenuator switch settings. When cable 
lengths are unknown, or the cable is other than the recommended cable 
(Table 2-1), signals must be compared at the Hub to identify which 
Equalizer board settings are needed. See page 37. 
IF you are using … 
THEN go to ... 
Recommended Cable  
Page 19 
Non Recommended Cable or when 
Cable Lengths are Unknown  
Page 37 
 
Refer to Site Wiring Requirements. Table 2-1 (page 19) to determine the 
requirements for your site. 
 
Description 
 
Instructions 
Recommended Cable