Siemens X-400 사용자 설명서

다운로드
페이지 148
Product Description of SCALANCE X-400 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
C79000-G8976-C186-03 
37
The modules in the individual slots have the following function (slot 1 is reserved 
for a power supply unit): 
●  Slot 2 
Power module 
The input voltage of 24 V DC is transformed to the internal supply voltage. The 
module has two 4-pin sockets for connecting a redundant power supply and for 
connecting the signaling contact and protective earth. 
●  Slot 3 
Digital input module 
The input module has two 5-pin sockets for connecting eight digital inputs that 
allow different signaling modes. 
●  Slot 4 
CPU module 
-  Contains the processor that provides the management functionality. 
-  C-PLUG for storage of parameter assignment. 
-  DIL switch for the redundancy manager function and to specify the ring 
ports. 
-  SELECT/SEL button for switching over the display modes, for resetting to 
the factory default settings and to define the fault mask. 
-  LED display of the display modes DMode A through DMode D. 
●  Slot 5 
Contains two RJ-45 jacks allowing attachment of electrical (twisted pair) con-
nections (10, 100, 1000 Mbps). 
As an option, slot 5 allows the use of an optical gigabit module with two ports 
(1000Base-SX or 1000Base-LX). 
●  Slots 6 and 7 
Optional use of two optical fast Ethernet modules (100 Mbps) each with two 
ports (100Base-FX). 
●  Slot 8 
No function in system. 
●  Slot 9 through 11 
Each contains four RJ-45 jacks allowing attachment of 12 electrical (twisted 
pair) connections in total (10, 100 Mbps). 
These cannot be used by media modules.