Siemens X-400 사용자 설명서

다운로드
페이지 148
Product Description of SCALANCE X-400 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
C79000-G8976-C186-03 
39
3.1.1 Power 
Module 
The power module is inserted in slot 2. 
The power can be fed into the power module redundantly over two inputs. The two 
power inputs are isolated from each other, there is no power distribution. If redun-
dant power feed-in is used, the switch is supplied solely by the section of the 
power module with the higher output voltage. 
The front 4-pin connector is used for the power supply. The input voltage is 24 V 
DC (20.4 – 28.8 V). The signaling contact supplies the fault status at the rear 4-pin 
connector. If there is a fault, the contact opens. 
 
F
L 1
L 2
R M
S T B Y
D M 1
D M 2
P 1
P 2
P 1
P 2
P 3
P 4
P 1
P 2
P 3
P 4
P 1
P 2
P 3
P 4
I N 1 / I N 5
I N 2 / I N 6
I N 3 / I N 7
I N 4 / I N 8
2
3
4
1 1
8
9
1 0
7
6
5
Figure 3-5 
Slot of the power module