Document No. 10-300077, Issue 2
3-13
Configuring System Information
Setting the Temperature System
You can set the upper and lower temperature warning systems for the switch 
backplane and slot 1. These warning systems cause the following to happen 
if the temperatures you set are reached:
Shutdown Temperature—The switch shuts down if this 
temperature is reached. 
Upper Warning Temperature—The switch generates an alarm if 
this temperature is reached. If the Shutdown Temperature is 
reached, once the temperature drops below the Upper Warning 
Temperature
, the switch restarts.
Lower Warning Temperature—The switch generates an alarm if 
this temperature is reached. Once the temperature rises above this 
temperature, the alarm is cleared.
Low Limit Temperature—The switch generates an alarm if this 
temperature is reached. 
 for the default temperature system settings. You can set the 
temperature system using either the Web Agent or the CLI.
Web Agent 
Procedure
To configure the temperature warning systems: 
1.  In the navigation pane, expand the System > Configuration folders, and 
then click Temperature System. The Temperature System Web page is 
displayed in the content pane. See 
.
Figure 3-7.  Temperature System Web Page for P580