User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 3
2.  In the Slot 1 Sensor and Backplane Sensor fields, enter the desired 
temperature warnings. 
* Note:  The P882 does not display the current temperature of the 
backplane. In the Current Temperature field, the switch 
displays 
--
.
* Note:  If a redundant Supervisor module is installed, the Slot 2 Sensor 
column displays.
* Note:  You cannot change settings for the backplane temperature 
sensors on the P882. If you attempt to change the settings, the 
switch displays the following error message:
Set Limits for Backplane Sensor failed - 
failure writing to sensor
3.  In the CPU Sensor fields, enter the desired temperature warnings.
4.  Click APPLY to save your changes, or DEFAULTS to reset the fields to 
their default settings. 
5.  If you change the temperature ranges for the active supervisor, you must 
synchronize the active and standby supervisors to copy the temperature 
settings to the standby supervisor. 
CLI Command
To check the temperature status, use the show temperature CLI command. 
To set the temperature thresholds, use the following CLI commands: 
(configure)# 
set temperature {supervisor-slot | backplane-
sensor | cpu-sensor | probe} shutdown <temperature>
(configure)# 
set temperature {supervisor-slot | backplane-
sensor | cpu-sensor | probe} warning {upper | lower | low-limit} 
<temperature>