Avaya C460 사용자 설명서
Chapter 2 Avaya C460 CLI Commands
152
Avaya C460 Reference Guide
show environment power
User level: read-only, read-write, admin.
Use the show environment power command to display the current power
configuration for the switch, the total power available to the system, and amount of
power currently in use.
L The “Main Power” includes two supervisor modules and the fan module,
Use the show environment power command to display the current power
configuration for the switch, the total power available to the system, and amount of
power currently in use.
L The “Main Power” includes two supervisor modules and the fan module,
irrespective of the number of supervisor modules installed.
L The “Main Draw” column shows the demand for an I/O module whether its
slot is enabled or not.
The syntax for this command is:
show environment power
Example:
Total working fans
• 9
• 8
• less than 8
• 8
• less than 8
Fans not installed
• No fan tray installed
C460 > show environment power
PSUs Configuration Admin: redundancy
PSUs Configuration State: no redundancy (2 active PSU(s))
Power Available Drawn Remaining
----- --------- ----- ---------
Main 411W 411W 0W
PoE 1589W 0W 1489W
Slot
Module Type
Active Enabled
Priority
Main
Draw
PoE
Budget
PoE
Draw
Fault
----
---------------
------ -------
-------- ----
------
----
-----
1 M460ML-SPV
Y
Y
critical
68W
2 M460ML-SPV
Y
Y
critical
68W
3 M4612ML-G
Y
Y
low
59W
4 M4648ML-T-2G-PWR
Y
Y
high
48W
720W
100W
5 M4648ML-T-PWR
Y
Y
low
48W
720W
0W
6 M4648ML-T-2G
Y
Y
low
70W
* Fans power consumption: 45(W)