Avaya P880 사용자 설명서

다운로드
페이지 43
                   23
610-0184-095
June 14, 2001
Workaround:  
Flush the L3 Forwarding Table before changing the L3 Forwarding 
Cache Max Entries value.
Option 82 for DCHP
The following problems have no workarounds: 
The switch does not add relay agent information (option 82) 
to a BOOTP request. 
The option 82 relay agent does not check frames for the 
IPSEC authentication header or IPSEC encapsulating security 
payload. 
PCMCIA
The following problem has no workaround:
Text files copied from the PCMCIA card cannot be read.
Problem:  
The 80-Series Supervisor module will not fully reset if you initiate a 
reset from either the CLI or the web agent after you perform a 
command that involves reading from, or writing to, the PCMCIA 
card.
Workaround:  
Power the switch off and then on after you read from or write to the 
PCMCIA card.
Point-to-Point Protocol (PPP) and Telnet
The following problems have no workaround: 
A Telnet session to the serial port via PPP may time out 
during attempts to transfer large files, such as executable 
images, to a Trivial File Transfer Protocol (TFTP) server. This 
does not terminate the file transfer. An in-progress TFTP file 
transfer ends only after the file transfer is completed.
A new baud rate may take effect before the current PPP 
connection is terminated if the baud rate change command is 
entered more than once. This results in the termination of 
the PPP connection. This requires re-establishment of a PPP 
connection.