Deployment tasks  21  
 
 
Example: miniroot preparation 
The following procedure is an example of a miniroot preparation for ProLiant servers. 
1. 
Unpack the stock Solaris miniroot: 
# /boot/solaris/bin/root_archive unpack .../boot/x86.miniroot \ 
> /var/tmp/mr 
The miniroot is expanded under 
/var/tmp/mr
2. 
Install the Smart Array driver into the miniroot, as described in the HP Smart Array Controller Driver 
for Solaris 10 User Guide 
at 
the miniroot at this time. 
3. 
Install the Broadcom NetXtreme II driver into the miniroot: 
# cd /var/tmp 
# gunzip -c .../BRCMbnx-3.5.1-solaris10-i386.tar.gz | tar vxf - 
# cd BRCMbnx-3.5.1-solaris10-i386/bnx 
# pkgadd -R /var/tmp/mr -d ‘pwd‘/BRCMbnx.pkg BRCMbnx
 
4. 
For Rapid Deployment Pack or custom ISO images, install the 
HPQnetstrategy
 package: 
# cd /var/tmp 
# gunzip -c .../HPQdeploykit-1.0.0-solaris10-i386.tar.gz | tar vxf - 
# cd HPQdeploykit-1.0.0-solaris10-i386/tools 
# pkgadd -R /var/tmp/mr -d ‘pwd‘/HPQnetstrategy.pkg HPQnetstrategy
 
5. 
Repack the miniroot: 
# cd /var/tmp 
# /boot/solaris/bin/root_archive pack /var/tmp/x86.miniroot.proliant \ 
> /var/tmp/mr
 
The new miniroot 
/var/tmp/x86.miniroot.proliant
 is now ready for use with ProLiant 
servers.