HP (Hewlett-Packard) 10 사용자 설명서
Deployment tasks 21
Example: miniroot preparation
The following procedure is an example of a miniroot preparation for ProLiant servers.
1.
Unpack the stock Solaris miniroot:
# /boot/solaris/bin/root_archive unpack .../boot/x86.miniroot \
> /var/tmp/mr
> /var/tmp/mr
The miniroot is expanded under
/var/tmp/mr
.
2.
Install the Smart Array driver into the miniroot, as described in the HP Smart Array Controller Driver
for Solaris 10 User Guide at
for Solaris 10 User Guide at
the miniroot at this time.
3.
Install the Broadcom NetXtreme II driver into the miniroot:
# cd /var/tmp
# gunzip -c .../BRCMbnx-3.5.1-solaris10-i386.tar.gz | tar vxf -
# cd BRCMbnx-3.5.1-solaris10-i386/bnx
# pkgadd -R /var/tmp/mr -d ‘pwd‘/BRCMbnx.pkg BRCMbnx
4.
For Rapid Deployment Pack or custom ISO images, install the
HPQnetstrategy
package:
# cd /var/tmp
# gunzip -c .../HPQdeploykit-1.0.0-solaris10-i386.tar.gz | tar vxf -
# cd HPQdeploykit-1.0.0-solaris10-i386/tools
# pkgadd -R /var/tmp/mr -d ‘pwd‘/HPQnetstrategy.pkg HPQnetstrategy
5.
Repack the miniroot:
# cd /var/tmp
# /boot/solaris/bin/root_archive pack /var/tmp/x86.miniroot.proliant \
> /var/tmp/mr
> /var/tmp/mr
The new miniroot
/var/tmp/x86.miniroot.proliant
is now ready for use with ProLiant
servers.