DELL MD3220 사용자 설명서

다운로드
페이지 260
Configuration: Disk Groups and Virtual Disks
133
• Redundancy mismatches error—The first 10 redundancy mismatches that 
are found on the virtual disk are reported to the event log.
• Unfixable error—Data could not be read and parity or redundancy 
information could not be used to regenerate the data. For example, 
redundancy information cannot be used to reconstruct the data on a 
degraded virtual disk. The error is reported to the event log. 
For more information, see the PowerVault Modular Disk Storage Manager 
online help topics.
Changing Media Scan Settings
To change the media scan settings:
In the AMW, select the Logical tab and select any virtual disk.
Select Virtual Disk Change Media Scan Settings.
The 
Change Media Scan Settings window is displayed.
Deselect Suspend media scan if selected.
In Scan duration, enter or select the duration (in days) for the media scan.
The media scan duration specifies the number of days for which the media 
scan runs on the selected virtual disks.
To disable media scans on an individual virtual disk, select the virtual disk 
in the 
Select virtual disks to scan area, and deselect Scan selected virtual 
disks.
To enable media scans on an individual virtual disk, select the virtual disk 
in the 
Select virtual disks to scan area, and select Scan selected virtual 
disks.
To enable or disable the consistency check, select either With consistency 
check or Without consistency check.
 
NOTE: 
A consistency check scans the data blocks in a RAID Level 5 virtual 
disk, or a RAID Level 6 virtual disk and checks the consistency information for 
each block. A consistency check compares data blocks on RAID Level 1 
mirrored physical disks. RAID Level 0 virtual disks have no data consistency.
Click OK.
book.book  Page 133  Monday, June 21, 2010  11:00 AM