Maintenance
Maintenance Requirements 
All maintenance must be 
carried out with the power switched off.
Failure to comply may result in serious 
injury!
On completion of maintenance, ensure that 
replaced parts and/or any tools used have been 
removed from the machine before starting it up. 
Periodic Maintenance 
‰
Remove chips from the machine, preferably 
with cloth) 
‰
Remove chips from the coolant tank and 
change coolant regularly (see Coolant
section) 
‰
Top up the coolant level (see Coolant)
‰
Check the wear of the blade and change if 
necessary (see Changing the Saw Blade)
‰
Empty the chips out of the base. 
‰
Clean the vise and lubricate all the joints 
and sliding surfaces, using good quality oil. 
‰
Attend to daily, weekly and annual 
lubrication recommendations (see the 
Lubrication section) 
Coolant
The coolant tank access door is located on the 
back of the cabinet stand. Remove four hex cap 
screws with a 5mm hex wrench. Check coolant 
level in the coolant tank periodically and top off if 
necessary. Coolant can also be added by 
pouring directly on the table, which will drain into 
the tank through the chip strainer.
Remove excess chips periodically from the tank. 
Use the coolant level gauge to check the coolant 
level.
Changing the Saw Blade 
The cold saw must not be 
connected to the power source when 
changing saw blades. Failure to comply may 
result in serious injury!
To change the saw blade: 
1.  Switch off the machine. 
2.  Release the lower disc guard. 
3.  Move the lower guard upwards. 
4.  Remove the blade and replace it with a new 
one.
5.  To secure the saw blade, reverse the 
preceding steps. 
Air Prep Unit – FK350-SX only 
The Air Prep Unit regulates the air pressure 
supplied to the saw. It is located in the cabinet 
stand and is accessible through the access door 
located below and to the left of the control panel.
Referring to Figure 13, it consists of a pressure 
regulator
pressure gaugewater trap and 
lubricator. Air pressure (90lbs. minimum) is 
supplied to the air intake valve located near the 
bottom of the cabinet on the left side. The 
pressure regulator should be adjusted to 90–
120lbs. 
Required Maintenance: 
‰
Check weekly. 
‰
Drain water from the trap when the level 
exceeds the redline. 
‰
Adjust to 2 –3 drops/minute. Refill oil when 
the level drops below the lower redline. Do 
not exceed past the upper redline. 
Figure 13