Wilton FK350-4 사용자 설명서

다운로드
페이지 44
8
Features
Miter Cutting Head 
The miter cutting head is the unit that cuts the 
material and consists of a cast iron base, blade 
support unit and guard, transmission unit, and 
motor. The depth of cut is set by adjusting the 
depth cut stop. The miter cutting head swivels 
and locks into -45º, 90º, and +45º by means of a 
locking mechanism. Depressing the mechanism 
overrides the lock, permitting the head to adjust 
to any position between -45º and +45
q.
Miter Position Lock 
The miter position lock secures the miter cutting 
head from movement. The miter is secured 
when the lock is pushed all the way to the left 
and can be positioned when the lock is moved to 
the right. 
Self-centering Vise 
The self-centering vise holds the work piece in 
place during cutting. The work piece is secured 
in the vise by turning the vise handles.
FK350 Controls 
The control panel consists of the Power (On/Off) 
switch and High/Stop/Low switch, and an 
integral coolant system. To operate the 
machine, the Power switch must be set to on
and the High/Stop/Low switch must be set for Hi
or Low. Then depress the trigger handle to start.  
FK350-SX Controls 
This machine features a 2-speed motor, feed 
speed control, an integral coolant system, and 
two modes of operation; manual mode, and 
semi-automatic mode. In semi-auto, the 
complete cut cycle is initiated via push button.  
The semi-auto cut cycle closes the vise 
clamping the material, powers the head down 
completing the cut, then raises the head, and 
opens the vise.  In manual mode, head up/down, 
and vise open/close is initiated by switches. 
Trigger Handle 
The trigger handle (Figure 1) is located on the 
operating lever used to raise and lower the saw. 
It contains a micro-switch, which is activated 
when the operator depresses the run trigger.
Figure 1 
Flood Coolant System 
The coolant pump must be 
submerged before operating to prevent 
damage to the pump.
Coolant is dispensed directed onto the saw 
blade from a coolant fitting on the upper blade 
guard. Coolant is provided through tubing from 
the coolant pump (Figure 2) in the machine 
base.
Adjust the coolant flow valve on coolant fitting to 
achieve desired flow. When the coolant switch is 
in the ON position, flow starts when the drive 
motor is started. Turning off the coolant switch 
stops coolant flow. 
This coolant system can operate with either a 
soluble oil base coolant or water-soluble 
synthetic coolant. Coolant should be changed 
regularly. Some recommended brands are DoAll
and Lenox. These coolants are available at your 
local industrial distributor. 
Figure 2