Smeg P106 사용자 설명서

다운로드
페이지 14
 
Instructions for the installer
 
 
 
25 
5. Adapting to different types of gas 
 
 
 
 
 
Before performing any cleaning or maintenance work, detach the hob from the 
electrical socket.
 
 
The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar.  
For functioning with other types of gas the nozzles must be replaced and the primary 
air adjusted. 
To replace the nozzles and regulate the burners, you have to remove the top as 
described in the following paragraph. 
 
5.1  Removing the hob 
Remove all of the burner components by following the numerical sequence shown in 
the figure: 
•  remove all of the knobs (1) by pulling them upward; 
•  remove the grids (2), lifting up one of the two horizontal spokes
•  remove the burner caps (3) and flame caps (4); 
•  with wrench A (supplied), open the bayonet clamps on the burner rings by levering 
on guides B
•  after having removed all of the above-described components, raise the surface to 
access the burners and gas taps.