BREWER OVERALL CHECK-OUT 
BREWER CHECK-OUT 
 
These checks should be performed: 
 
When the brewer is installed 
During any service call on the brewer 
During any subsequent follow-up call 
 
IMPORTANT: 
Tank must be full of water before pressing POWER key "
ON
".    
Heating elements will be damaged if allowed to operate without  
being fully submerged in water. 
Damage caused by operating the brewer without water in the tank 
is NOT COVERED BY WARRANTY
 
1.
Clean spray disk 
 
2.    Check spray disk gasket.  Be sure it is installed inside of the 
       brew head cup. 
 
3.    Check operation of Power Switch(es), Brew Switch and Brew 
       Cancel Switch. 
 
4.    Check the brew temperature at the brew head: 
       a.    Install a paper filter in the brew chamber, then install the  
              brew chamber under the brew head.  Set an empty          
              container in position under the brew head. 
       b.    Withdraw the brew chamber slightly, and insert the          
              temperature probe of a digital thermometer into the brew 
              chamber so that the tip is near the discharge hole. 
              Be sure the brewer is up to temperature ( "ready-to-brew" 
              light is on), then start a brew. 
       c.     At this location, temperature should be near 
                     190ºF for coffee 
                     195ºF for tea 
 
5.    Check the water delivery volume. 
 
6.    Where applicable, check operation of warmers and warmer 
       switches. 
 
7.    Disconnect brewer from electric power.  Remove top panel and 
       check hoses and connections for water leaks. 
 
8.    Where applicable, check hot water faucet for operation and 
       leaks. 
CAUTION:  
SHOCK HAZARD 
 
Always disconnect the brewer 
fro electrical power before     
servicing or cleaning. 
 
CAUTION:  
BURN HAZARD  
 
Brew water is extremely hot. 
Exposed surfaces of the brew 
chamber and airpot ,decanter  
or thermal server may be HOT 
to the touch, and can cause  
serious burns. 
 
If any problems are                
encountered with the operation 
of this brewer, please refer to 
the TROUBLESHOOTING 
GUIDE, beginning on page 10. 
 
IMPORTANT: 
When operating the brewer for 
the first time, the tank must be 
filled with water BEFORE     
connecting to electric power. 
Place an empty container under 
the brew head, then pour        
water into the pour-over     
opening until water flows from 
the brew head.  When all      
dripping stops, remove and 
empty the container.  It is now 
safe to connect brewer to    
electric power. 
Fill Water Tank