(1)  Leakage  of  compressor:  mainly  because  of  serious  vibration, 
the  motor  coil  of  compressor  contacts  with  the  shell,  the  coat  of 
enameled wire will  come  off  some where  and  connect with  shell. 
Other  reasons  may  be  over  voltage,  insufficient  of  voltage, 
adverse  circumstances  (temperature  too  high,  ventilation  and 
heat  radiation  to  bad)  for  freezer,  thermal  protection  unit  out  of 
order,  etc.  They  will  make  the  motor  coil  over  temperature, 
insulation  material  loose,  insulation  is  damaged  then  electricity 
will occur. 
(2)  Leakage  of  motor  connection  terminals:  the  connection 
terminals  of  fully  enclosed  compressor  are  made  from  high 
temperature  soda  glass  sintered  ceramics,  around  the  terminals 
are  filled  with  a  high  polymer.  The  terminals  and  insulation 
material must  have  the  same linear  expansion  coefficient,  the for 
requirement  between  terminals  and  the  shell  is  more  than  0.5 
million  ohm.  The  reason  of  terminal  leakage is  that  soda  glass  is 
broken or there are conductive materials such as water, dirt, etc., 
adhered to terminals. 
 
MAINTENANCE SERVICE AND TROUBLE SHOOTING
 
Maintenance  Service  and  Trouble  Shooting
 
If  electricity  leakage  occurs  outside  the  compressor,  please  use 