tetra chloromethane or alcohol to clean it. If the leakage occurs in 
the inner of compressor, it needs to be changed. 
(3)  Leakage  of  temperature  controller:  because  of  too  long  a 
period of service or too high temperature, or too much dirt, or too 
high  humidity,  there  may  be  electricity  leakage.  If  it  has  been 
defined  that  there  is  leakage  of  temperature  controller,  please 
change. 
(4)  Leakage  of  starting  relay:  during  mounting  and  repairing, 
screw  of  relay  lead  is  easy  to  contact  the  shell  and  leakage  will 
then  occur.  If  you  suspect  the  relay  is  bad,  check  it.  If  there  is 
leakage, please make the connections again and leave a piece of 
insulation paper under the screw. 
(5)  Leakage  of  fan:  because  of  too  high  humidity  of  freezer 
environment or  a bad  fan  controlling  unit,  the  fan is  burned  after 
long  time  operation  and  thus  causes  leakage.  Using  voltammeter 
to  measure  the  insulation  resistance  between  each  respective 
connection  terminal  and  the  freezer  body,  if  the  resistance  is  too 
little, means there is leakage caused by humidity; if the resistance 
 
Is  zero,  means  the  fan  coil  is  burned  or  short-circuited.  Please 
change the fan. 
MAINTENANCE SERVICE AND TROUBLE SHOOTING
 
Maintenance  Service  and  Trouble  Shooting
 