20
The condenser must be unscrewed 
to make the sensor cable opening 
accessible.
1.  Unscrew  condenser  screws 
(6 pcs.) and fold out condenser 
at an angle.
Important!
Make sure that no pipes are bent.
Opening for external temperature sensor
Model LGex 3410
Remove upper drawer before beginning work.
2.  Drill marked section at the back of 
appliance.
3.  Pull out strain relief device (top left 
of interior container).
4.  Feed sensor through opening 
and secure sensor cable with 
strain relief device.
Important!
Position the sensor at the top of the interior container. The sen-
sor must not come into contact with objects so that only the air 
temperature is measured.
   Important!
5.  Close the sensor cable opening 
at the back of the appliance with 
the sealant provided.
6.  Screw condenser back on.
Important!
Only  drill  the  outer  wall  of  the 
housing.
Do not drill too far.
1.  Drill marked section on the back of 
the appliance.
Opening for external temperature sensor
Model LGUex 1500
2.  Pull out strain relief device (bot-
tom left of interior container).
3.  Feed sensor through opening and 
secure  sensor  cable  with  strain 
relief device.
Important!
Position the sensor at the top of the interior container. The sen-
sor must not come into contact with objects so that only the air 
temperature is measured.
   Important!
4.  Close the sensor cable opening at the back of 
the appliance with the sealant provided.