14
Certain safety code requirements exist for the installation 
of gas ovens; refer to the beginning of Section 2 for a list of 
the installation standards. In addition, because a the oven is 
equipped with casters, the gas line connection shall be made 
with a connector that complies with the Standard for Connectors 
for Movable Gas Appliances, ANSI Z21.69 (in U.S.A.), as well 
as a quick-disconnect device that complies with the Standard 
for Quick-Disconnect Devices for Use With Gas Fuel, ANSI 
Z21.41 (in U.S.A.).
D. PS770 Propane conversion
Four items have to be changed, to change the oven to LP:
1.  Adjust internal burner air shutters.
2.  Replace main Orifices
3.  Replace (and adjust) the spring in the main valve (see LP 
kit)
4.  Adjust modulating valve bypass settings.
Disconnect the manifold unions closest to the main burner, and 
remove the manifold assemblies (four screws each). Remove the 
addition four screws holding the burner cores and slide out each 
burner core (leaving the ignition and sense wires connected). 
Adjust the internal air shutters fully open, and replace the cores.
Replace the main orifices on the manifold assemblies with the 
LP units, and replace the manifold assemblies. Reconnect the 
unions. Replace the valve spring with the LP spring, and adjust 
the downstream pressure to get 7″ WC.
Adjust the bypass screws in the side of each modulating valve 
to approximately 1/6 turn from fully closed. If this setting is too 
low, the burners will shut off when trying to modulate. If it is 
too open, the unit will tend to gradually raise up in temperature 
at standby.
Figure 2-14 - Gas Burner/Blower Motor and Piping Assembly
Gas Burner