BLOOMFIELD WVG-136RWT 사용자 설명서

다운로드
페이지 30
ITEM 
 
   1. 
 
 
  a6. 
 
  
   8. 
 
   9. 
 
 
a10. 
 
 
a11. 
 
 
  12. 
 
 
a15. 
 
  16. 
 
  18. 
 
 
 
  19. 
 
 
  22. 
 
  23. 
 
  28. 
 
 
a31. 
 
 
  38. 
 
  40. 
 
 
  41. 
 
 
  42. 
 
 
  43. 
 
  44. 
 
 
  53. 
 
 
  56. 
DESCRIPTION 
 
NAMEPLATE 
 
 
FIRE SUPPRESSION    
AGENT TANK (1.5 gal.) 
 
ADJUSTABLE (FRONT) LEG  
 
RIGID (REAR) CASTER 
 
 
MANUAL PULL STATION  
 
 
FUSIBLE LINKS 
 
 
LOWER REAR ACCESS 
PANEL 
 
DISCHARGE NOZZLE 
 
GREASE BAFFLE  
 
PRE-FILTER ASSEMBLY  
 
 
 
HEPA/CHARCOAL FILTER 
PACK 
 
GREASE CUP  
 
GREASE TROUGH 
 
VENTILATOR EXHAUST 
DUCT 
 
STATUS INDICATOR 
 
 
POWER CORD 
 
WARMER RELAY 
 
 
POWER CONTACTOR  
 
 
BUILDING FIRE ALARM       
RELAY 
 
GROUND LUG 
 
INTERLOCK TERMINAL 
 
 
FILTER INTERLOCK 
SWITCHES 
 
VENTILATOR FAN 
COMMENT 
 
Lists Manufacturer, Model and Serial Number information. 
Also lists electrical specifications. 
 
Container for Ansulex™ Low-pH liquid fire suppression liquid.  
 
 
Allows the unit to be leveled. 
 
Allows the unit to be easily positioned by lifting the front of the unit 
slightly. 
 
Provides a means of manual activation of the  fire suppression system.  
PULL ONLY IN CASE OF FIRE! 
 
Automatically activates fire suppression system in the event of fire on 
the griddle. 
 
Allows access to Ansul® fire suppression agent tank (a6) and controls 
also access to main power contactor (41). 
 
Fire suppression media discharges here (2 places). 
 
Extracts and drains most grease and moisture from the air flow. 
 
Comprises the PRE-FILTER FRAME and a replaceable 
PRE-FILTER.  Stops larger particles of grease from  reaching the    
FILTER PACK for reduced maintenance costs. 
 
Stops most grease and smoke particles.   Also assists in some cooking 
odor removal. 
 
Collects grease/moisture drained from grease trough (23). 
 
Directs grease/moisture removed by grease baffle to grease cup. 
 
Exit point for ventilator airflow - on top left rear of unit. 
DO NOT BLOCK 
 
Displays status of fire suppression system (COCKED - FIRED) If 
FIRED, a buzzer will sound continuously. 
 
6’ cord and cap.   Plug for NEMA 15-60R (receptacle by user). 
 
Provides power to roll warmer section.  Energized at all times except 
during fire safety shut-down. 
 
Energizes griddle only while ventilator section is  sensed as              
operational. 
 
Reports fire alarm condition to building fire management system. 
 
 
Ground wire of power cord connects here. 
 
Provides connection for shut-down control by building fire                
management system. 
 
Proper installation of grease baffle and filter pack close these switches 
in ventilator sensor circuit. 
 
Provides air movement for ventilation. 