DESCRIPTION 
POWER SWITCH 
 
 
POWER ON INDICATOR 
 
CHECK FILTERS ALARM 
INDICATOR 
 
REPLACE PREFILTER 
ALARM INDICATOR 
 
REPLACE FILTER PACK 
ALARM INDICATOR 
 
SERVICE REQUIRED 
ALARM INDICATOR 
 
 
 
GRIDDLE TEMPERATURE 
CONTROL 
 
INDICATOR LIGHT 
WARMER TEMPERATURE     
CONTROL  
 
POWER ON INDICATOR 
 
THERMOMETER (optional) 
 
 
HUMIDITY CONTROL 
 
 
DRAWER CATCH 
 
DRAWER STOP 
 
 
DRAWER ROLLERS 
 
POWER SWITCH (RWT) 
 
CONTROLLER (RWT) 
COMMENT 
Energizes blower motor.  If, after 10 seconds, proper conditions 
are met, appliance is energized. 
 
GREEN.  Glows when POWER switch is 
ON
. 
 
AMBER.  Glows if one or more filters are out of position.  Check 
all filters and baffles for proper installation. 
 
AMBER.  Glows when PREFILTER is approaching the end of its 
service life and must soon be replaced. 
 
AMBER.  Glows when FILTER PACK is approaching the end of 
its service life and must soon be replaced. 
 
RED.  Glows when PREFILTER and/or FILTER PACK has 
reached the end of its service life and is too loaded to allow   
sufficient air flow.  Filter MUST be replaced.  Appliance is SHUT 
DOWN 
until expended filters are replaced. 
 
Thermostat control of temperature of one griddle half. 
 
 
AMBER.  Glows when heating element is energized. 
Infinite switch control of temperature of one warmer drawer. 
 
 
AMBER.  Glows when associated temperature control is turned ON. 
 
Reads temperature inside drawer cavity 
Must be ordered at time of initial build. 
 
Slide control of shutters to control air circulation within the warmer 
drawer. 
 
Holds drawer closed. 
 
Prevents drawer from opening too far.  Spring loaded to permit easy 
removal of drawer. 
 
Support drawer and allow it to open and close smoothly. 
 
Energizes unit (RWT-style only) 
 
Controls cavity temperature.  Readout displays setpoint and actual 
temperature information.  UP ARROW / DOWN ARROW keys allow 
modification of setpoint temperature. (RWT-style units only) 
FEATURES & OPERATING CONTROLS (continued) 
GRIDDLE SECTION CONTROLS 
OPTIONAL WARMER SECTION CONTROLS 
* See 
PRECAUTIONS & GENERAL INFORMATION, pages 6 & 7 for special procedures regarding            
       prefilters and filter packs. 
VENTILATOR SECTION CONTROLS 