Vermont Casting DVBR42 사용자 설명서

다운로드
페이지 40
25
DVBR Series Direct Vent Gas Fireplace
20000584
�����
���������
����
Right Cover 
Log
Center Log
Left Cover Log
LG391
Fig. 52  Place Left and Right Cover Logs and Center Log on grate.
��������
���������
����
Log Top Right 
(DVBR42 ONLY)
Left Cross Log
Left Front Log
LG392
Fig. 53  Place Left Front Log, Left Cross Log and Log Top Right.
Top logs must be placed properly onto 
notches.
Flame & Temperature Adjustment
For fireplaces equipped with Hi/Lo valves, 
flame adjustment is accomplished by rotating 
the Hi/Lo adjustment knob located near the 
centre of the gas control. (Fig. 54 & 55)
Flame Characteristics
It is important to periodically perform a visual 
check of the pilot and the burner flames. 
Compare them to Figures 56, 57 & 58. If any 
of the flames appear abnormal call a service 
person.
Inspecting the Venting System
This appliance venting system was designed 
and constructed to develop a positive flow 
adequate to remove flue gases to the outside 
atmosphere.
Any foreign objects in the venting system, 
except those designed specifically for the 
venting system, may cause spillage of flue 
gases.
To inspect the venting system, make sure the 
main gas valve is off.  Remove glass frame 
(See Glass Frame Removal Section).  Using 
a flashlight, check the area above the baffle 
in the combustion dome.  Clean if necessary.
LO
 
HI
 
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Turn 
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
Fig. 55  flame adjustment knob for SIT valve.
Fig. 54  Flame adjustment knob for Honeywell valve.
��
��
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99   djt
HV102
3/8” - 1/2”