Radar Installation Manual
2.7
CHART PLOTTER CONNECTIONS AND SET UP
The following instructions refer to Dome Antennas; refer to Open Array for connections.
2.7.0 CP180 & CP180i Connections
PWR & ACC 1 Cable
A switch MUST be connected
to turn the Radar On or Off
to turn the Radar On or Off
Radar
Switch
Battery
Battery Switch
RADAR CABLE
WIRE COL. FUNCTION
BLACK
BLACK
DATA GROUND
ORANGE
DATA OUT+
YELLOW
DATA OUT-
BROWN
DATA IN+
RED
DATA IN-
GREEN
POWER ON/OFF SWITCH
BLUE
POWER ON/OFF SWITCH
BLACK
RADAR BATTERY GROUND
WHITE
RADAR BATTERY POSITIVE
PLOTTER CABLE
WIRE C L R FUNCTION
O O
GREEN
GND
No connection AUX OUT+
BROWN
BROWN
OUTPUT+ (TX+)
BLUE
INPUT+ (RX+)
BLACK
POWER- /GND
RED
POWER+
(Port 1)
(Port 1)
Breaker panel
Figure 2.7.0 - CP180 & CP180i Connections
Port Setup
When an optional Radar Antenna is connected, Port 1 of the NMEA In/Out Communication
Setup menu must be changed to RADAR as shown below for communications.
1. From the Chart page, press [MENU]. Move the ShuttlePoint knob to highlight SETUP
Setup menu must be changed to RADAR as shown below for communications.
1. From the Chart page, press [MENU]. Move the ShuttlePoint knob to highlight SETUP
MENU and press [ENT].