Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Installing the System 
23
Connecting the Hospitality Adjuncts 
Distance Limits
The distance limit between the switch and the IDI is 200 feet (61 meters). If you 
need a cable longer than the default 50 foot (15.2 meter) cable provided, order a 
Group 4 cable (100 feet; 30.5 meters) or a Group 5 cable (200 feet; 61 meters). 
See 
 for a list of cables.
NOTE:
If you locate the switch more than 50 feet (15.2 meters) from the MAP and 
are using the coresident INTUITY Lodging Call Accounting system on the 
MAP, the call accounting link limit of 50 feet (15.2 meters) must be taken 
into account. 
 shows how the call accounting link can be extended 
beyond this limit.
Cabling Diagram
 shows a detailed connection between a Processor Interface (PI) switch 
port (
si system) or Packet Gateway (PGATE) switch port (r system) and the DCIU 
card on the MAP.
Figure 6.
Switch-to-INTUITY Admin Link (X.25)
TN765
PI
TN577
PGATE
DCIU
Card
Switch
MAP
In
(J1)
Or
Out
(J2)
50 Ft.
ED1E434-11
Group 175
Cable
H600-210
Group 3
Cable
H600-347
Cable
«
«
«
«
«
« «
« «
IDI
pi2gp.cdr