Installing the System 
33
Connecting the Hospitality Adjuncts 
Test Procedure
Using the RS232 Mini-Tester (see the Note on 
), check the status of the link 
where the Equinox adapter connects to the null modem as shown in 
The leads marked with an asterisk are controlled by the INTUITY system, and the 
PMS controls the other leads. Translations for this connection begin on 
.
!
CAUTION:
After using a mini-tester to check data leads, you MUST remove the 
mini-tester from the connection. DO NOT leave the mini-tester in-line during 
actual operation.
With the mini-tester connected to only the Equinox adapter coming from the MAP, 
the mini-tester should show the following:
With the mini-tester connected to only the PMS at the null modem, the mini-tester 
should show the following:
With the mini-tester connected to the MAP and the PMS, but in an idle state, the 
mini-tester should show the following:
TD*
RTS*
DTR*
RD
CTS
DSR
CD
dark
dark
green
dark
red
dark
dark
TD*
RTS*
DTR*
RD
CTS
DSR
CD
dark
red
dark
red
dark
red
red
TD*
RTS*
DTR*
RD
CTS
DSR
CD
dark
red
green
red
red
red
red