Installing the System 
35
Connecting the Hospitality Adjuncts 
Co-Resident INTUITY Lodging Call Accounting
Link Using the DCE Port
This connection is used to transfer Call Detail Recording (CDR) information to the 
co-resident INTUITY Lodging Call Accounting software (Homisco). This 
connection is valid for a 
csi or si system.
Parts List
The DCE port on the switch (this port is found on the Processor Interface 
Cable of a 
csi system labeled as J2)
One M25A RS232 cable (or equivalent straight-through cable) 
(comcode 105193668)
One Equinox P/N:210068 DTE 10/10 adapter (DB25 DTE, 
comcode 406983155); se
One D6AP modular cord (comcode 102937604)
One Multi-Port Serial card on the MAP (comcode 407009406; J1P260AA1, 
List 12).
For this connection, use the first port on the card. This port is not marked 
on the card, but is administered in software as port TTYsaa.
Distance Limits
The distance limit from the switch to the MAP is 50 feet (15.2 meters). If the 
distance from the switch and the MAP is more than 50 feet (15.2 meters), or if the 
switch is an 
r system, see