Vermont Casting DVT38IN 사용자 설명서

다운로드
페이지 48
10
Chateau™
20011956
������
������������
����
ADJ.
S
Remote/Off
IPI
PO
WER
AUX
Learn
I
Continous
Pilot
Off/On
Junction Box
Main Module
FP1792
Fig. 11  Connect 120V AC electrical supply.
Main Module
Learn 
Button
Power Module
cover in place. Carefully remove the circuit board. 
Install batteries with dimpled side showing. (Fig. 
10) Carefully replace circuit board and back cover. 
Tighten screws.
FP1824
wall transmitter batteries
11/07
Install two (2) 
Batteries with 
Dimpled Side 
Showing
FP1824
Fig. 10 Inside view of wireless wall switch.
 
20.Locate the learn button on the main module. (Fig. 
11) Press and release the learn button using a pencil 
point. There will be a beep sound from the module. 
Then press any key on the hand-held remote control 
transmitter. Once the module’s internal receiver 
accepts the transmitter code, there will be a series 
of confirming beeps. If you are using the optional 
wall mountable remote control transmitter, press the 
learn button on the main module a 2nd time. There 
will be a beep sound from the module. Then press 
the ON button on the wall mountable transmitter. 
Once the module’s internal receiver accepts the 
transmitter code, there will be a series of confirming 
beeps.
21.The fireplace remote system is now ready for use 
and will respond to either wireless transmitter.
22.Reassemble access panel, burner assembly, gas 
supply connector, brick panels, logs, embers, 
andirons and lava rock in reverse order of removal. 
(Refer to Log, Lava Rock and Ember Placement 
section. 
23.Turn on gas supply and check that all connections 
are tight and leak free.
NOTE: If you need to test the inlet pressure and/or 
manifold pressure, there are two (2) test ports available 
along the right side front edge between the firebox side 
and outer casing. The upper test port is inlet pressure. 
The lower test port is manifold pressure. (Refer to 
Figure 8)
CAUTION: Turn off the gas supply before 
removing test port plug.
24.Using a 7/16” nut driver, remove the threaded plug 
from the test port.
25.Thread the supplied extension adaptor into the open 
test port.
26.Attach a 1/4” diameter pressure gauge flexible hose 
fully onto the barb of the adaptor.
27.Turn on gas supply and operate valve with remote 
control as needed to indicate gas pressure.
CAUTION: Turn off the fireplace and gas 
supply before removing test port adaptor 
and replacing plug.
28.After test, remove extension adaptor and replace 
plug securely.
29.Turn on gas supply and check that plugs are tight 
and leak free.
Special Feature for Cold Climates
This gas control system has the option of a continu-
ous pilot feature. This allows the user to change from 
a spark to pilot system to a standing pilot system for 
direct vent appliances during cold climate conditions to 
keep the firebox warm.
When the continuous pilot mode is activated and the 
fireplace is turned ON, the pilot will spark and light. 
When the fireplace is turned OFF, the pilot will stay ON 
when the main burner shuts OFF.
The continuous pilot mode can be activated or de-acti-
vated by the hand held remote control transmitter.