5.  Base Specifications Parameters 
 
 
64 
 
# Items 
Details 
Setting range (unit)
21102 add02 
(bit0) 
Servo 
parameter 
100-point 
compliance 
0:  The number of servo parameters is set to 64 
points. 
1:  The number of servo parameters is set to 100 
points when using the 100-point servo parameter 
compliant amplifier. 
(This is compatible from software version C1 and 
higher.) 
0/1 
 add02 
(bit1) 
External 
search 
time-out valid 
0:  Time-out check of the external search command 
(DDBS) is not performed. 
1:  Time-out is performed approx. 3 seconds after 
the external search command (DDBS) is issued. 
(This is compatible from software version C2 and 
higher.) 
0/1 
 add02
(bit2) 
RIO 
communi- 
cation 
interruption 
alarm invalid 
0:  The alarm “RIO communication interrupted” 
will occur if the remote I/O unit is not mounted. 
1:  Any alarm will not occur evenif the remote I/O 
unit is not mounted. Set “1” if the remote I/O unit 
is not used though CC-Link, MELSECNET/10, 
etc. is used. 
(This is compatible from software version C3 and 
higher.) 
0/1 
21103 add03
(bit0) 
 
Reserved for system. 
 add03
(bit1) 
Amp S/W 
automatic 
download 
valid  
(only C64T) 
Specify whether to perform or not the automatic 
download of the amp software when the power is 
turned ON. 
0: Disables download 
1: Enables download 
(This is compatible from software version C4 and 
higher.) 
0/1 
(Standard:0) 
21104 add04
(bit0) 
Sampling 
mode 
selection 
Select the sampling mode. 
(This is compatible from software version D0 and 
higher.) 
0:  Cycle monitor mode 
1:  NC alarm diagnosis mode 
When NC power is turned ON, cycle monitor mode is 
selected. 
0/1