Intel P3700 사용자 설명서

다운로드
페이지 47
 
Intel® Solid-State Drive DC P3700 Series 
 
Product Specification 
 
May 2015 
14 
 
330566-009US 
2.4  Environmental Conditions  
Table 11:  Temperature, Shock, Vibration 
Temperature 
Add-In card form factor 
2.5-inch form factor 
Temperature 
 
Operating
1
 
 
Non-operating
3
 
 
Ambient: 0 – 55
C / 0 -40
C
2
 
-55–95
 
Ambient: 0–35
C, Case: 0-70
Temperature Gradient
 
Operating  
 
Non-operating 
 
30
C/hr (Typical) 
30
C/hr (Typical) 
 
30
C/hr (Typical) 
30
C/hr (Typical) 
Humidity 
 
Operating 
 
Non-operating 
 
5–95% 
5–95% 
 
5–95% 
5–95% 
Shock and Vibration 
Range 
Shock
 
Operating 
 
Non-operating 
 
50 G Trapezoidal, 170 in/s 
50 G Trapezoidal, 170 in/s 
 
1,000 G (Max) at 0.5 msec 
1,000 G (Max) at 0.5 msec 
Vibration
 
Operating 
 
Non-operating 
 
2.17 GRMS (5-700 Hz) Max 
3.13 G
RMS
 (5-800 Hz) Max 
 
2.17 GRMS (5-700 Hz) Max 
3.13 G
RMS
 (5-800 Hz) Max 
Notes: 
1. 
Operating temperature implies ambient air temperature under defined airflow in Tables 12 and 13. 
2. 
0-55° C is for airflow from the server towards the card and 0-40° C is for airflow into the server. 
3. 
Please contact your Intel representative for details on the non-operating temperature range. 
4. 
Temperature gradient measured without condensation. 
5. 
Shock specifications assume the SSD is mounted securely with the input vibration applied to the  
drive-mounting screws. Stimulus may be applied in the X, Y or Z axis. Shock specification is measured  
using Root Mean Squared (RMS) value. 
6. 
Vibration specifications assume the SSD is mounted securely with the input vibration applied to the  
drive-mounting screws. Stimulus may be applied in the X, Y or Z axis. Vibration specification is measured  
using RMS value. 
Table 12:  Airflow Requirements for Intel SSD DC P3700 Series (Add-In Card) 
Airflow 
Direction 
Unit 
Ambient 
Temperature 
Intel
 
SSD DC P3700 Series 
400GB 
800GB 
1.6TB  
2TB 
Towards 
the server 
LFM 
40
200 
300 
300 
300 
Out of the 
server 
LFM 
55
200 
300 
300 
300 
NOTE:   For Add-In cards airflow can be for both the directions. Airflow specified is based on approach velocity.