PROBLEM
POSSIBLE CAUSE
SOLUTION
No.water.spraying.onto..
auger.screen.
•. Solenoid.valve.clogged.
•. Water.turned.off.
•. Solenoid.valve.defective.
•. Spray.nozzles.clogged.
•. Timer.defective.
•. Timer.not.set.properly.
•. Solenoid.valve.installed.incorrectly.
•. Remove.clog.
•. Turn.on.water.
•. Call.for.service.
•. Replace.nozzles.
•. Call.for.service.
•. Call.for.service.
•. Reinstall.solenoid.valve.so.arrow.is.pointing.
. in.correct.direction.
Water.flows.continuously.before.
controls.are.turned.on.
•. Solenoid.valve.is.stuck.open.
•. Solenoid.valve.installed.incorrectly..
.
•. Solenoid.valve.is.wired.incorrectly.
•. Timer.is.defective.
•. Timer.is.not.set.properly.
•. Solenoid.valve.is.defective.
•. Post.flush.setting.in.control.center..
. is.not.correct.
•. Call.for.service.
•. Reinstall.the.water.solenoid.valve.with.the..
. arrow.on.the.valve.pointing.in.the.direction..
. of.the.water.flow.
•. Call.for.service.
•. Call.for.service.
•. Call.for.service.
•. Replace.solenoid.valve.
•. Call.for.service.
Overload.protector.trips.frequently.
•. Disposer.is.overloaded.with..
. food.waste.
•. Do.not.overload.disposer.with.excessive..
. amounts.of.food.waste.
Cold.water.shuts.off.when.Waste.
Xpress.shuts.off.
•. System.being.shut.down.using.Line.
. Disconnect.switch.on.control.center.
•. Post.Flush.settings.on.circuit.board.in.
. control.center.are.not.to.specification.
•. Use.stop.and.start.push.buttons..Line..
. Disconnect.switch.is.only.de-activated.
. when.system.maintenance.is.required.
•. Call.for.service.
SYSTEM TROUBLESHOOTING