Troubleshooting
PROBLEM
CAUSE
SOLUTION
Disposer.motor.will.not.start.and.
water.does.not.flow.
•. No.incoming.line.power.
•. Line.disconnect.switch.is.not.on..
.
•. Line.disconnect.switch.has.been..
. reactivated.and.30-second.delay..
. has.not.yet.expired.
•. Line.Disconnect.switch.on.control..
. is.defective.
•. Start.switch.on.control..
. is.defective.
•. Stop.switch.on.control..
. is.defective.
•. Dip.switch.settings.on.circuit..
. board.in.control.center.may.not.be.
. to.specification.
•. Control.circuit.fuse.FNA2.is.blown.
•. 24.V.power.from.control.center..
. (control.circuit).is.low.or.not.present.
•. Turn.line.power.on.
•. Turn.line.disconnect.to."on".position..Wait..
. 15-20.seconds.before.attempting.to.start..
. system.to.allow.control.to.perform."self.test."
•. Wait.30.seconds.and.try.starting.again..
.
•. Call.for.service..
•. Call.for.service..
•. Call.for.service..
•. Call.for.service..
.
•. Replace.fuse.
•. Call.for.service.
Disposer.does.not.reverse.direction.
•. Control.center.has.been.reactivated..
. before.post-flush.delay.has.expired.
•. Wait.until.post-flush.is.complete.and..
. try.again.
Disposer.motor.stops.while.grinding.
but.water.continues.to.flow.
•. Control.center.wired.for..
. automatic.shut-off..
.
.
•. Disposer.is.jammed..
•. Disposer.motor.overload.protector..
. has.tripped.
•. Press.start.button..If.disposer.runs.for..
. 10.minutes.then.shuts.off,.the.automatic..
. shutoff.is.active..If.the.manual.setting.is..
. desired,.change.indicated.in.the..
. feature.section.
•. Press.stop.button.and.follow.directions.for..
. dejamming.in.disposer.installation.manual.
•. Press.stop.button..Locate.red.reset.button..
. on.front.of.disposer.electrical.cover...
. Press.to.reset..If.motor.had.been.running,..
. wait.five.minutes.for.the.motor.and.overload..
. to.cool.down.
Disposer.will.not.start.but..
water.flows.
•. Overload.protector.on.the.disposer..
. may.have.tripped.
•. Disposer.is.jammed.
•. Press.stop.button..Locate.red.reset.button..
. on.front.of.disposer.electrical.cover..Press..
. to.reset..If.motor.had.been.running,.wait..
. five.minutes.for.the.motor.and.overload.to..
. cool.down.
•. Press.stop.button.and.follow.directions..
. for.dejamming.that.were.supplied.with..
. the.disposer.
Water.flows.constantly.before.start.
button.is.pushed.
•. Water.solenoid.valve.is..
. installed.backward.
•. Water.flow.should.be.in.the.direction.of.the..
. arrow.on.valve.
Overload.trips.frequently.
•. Disposer.overloaded.
•. Do.not.overload.disposer.with.excess..
. amounts.of.garbage.and.water.
DISPOSER TROUBLESHOOTING