venting inStALLAtiOn
NOTICE: Do not seal termination 
cap to vent pipe. Cap must be 
removable  for  vent  inspection 
and maintenance.
INSTALLATION pRECAUTIONS
•  Wear  gloves  and  safety  glasses  for 
protection
•  Use extreme caution when using ladders 
or when on roof tops
•  Be aware of electrical wiring locations in 
walls and ceilings
The following actions will void the warranty 
on your venting system:
•  Installation  of  any  damaged  venting 
component
•  Unauthorized modification of the venting sys-
tem (Do not cut or alter vent components)
•  Installation  of  any  component  part  not 
manufactured  or  approved  by  FMI 
PRODUCTS, LLC
•  Installation  other  than  as  instructed  by 
these instructions
 WARNING: This gas fireplace 
and  vent  assembly  must  be 
vented  directly  to  the  outside. 
The venting system must NEVER 
be attached to a chimney serv-
ing a separate solid fuel burning 
appliance. Each direct vent gas 
appliance must use a separate 
vent system. Do not use com-
mon vent systems.
  WARNING:  Vent  pipe  air 
space  clearances  to  combus-
tibles are 1" on all sides except 
on  the  horizontal  sections, 
which  require  2"  clearances 
from the top of the pipe. Where 
the termination cap penetrates 
a combustible wall, 1" air space 
clearance is required.
NOTICE:  Read  these  instruc-
tions completely before attempt-
ing installation.
These models are tested and approved for 
use with FMI PRODUCTS, LLC (direct vent) 
pipe components and terminations.
The  venting  system  must  terminate  on  the 
outside of the structure and can not be at-
tached to a chimney or flue system serving a 
separate solid fuel or gas burning appliance. 
A  direct  vent  appliance  must  have  its  own 
venting system. DO NOT common vent this 
appliance.
These  models  are  approved  to  be  vented 
either horizontally through an outside wall or 
vertically through a roof or chase enclosure 
using the following guidelines:
•  When venting system terminates horizon-
tally  on  an  outside  wall,  you  may  install 
a standoff if the termination cap is to be 
installed  directly  on  a  combustible  finish 
such as vinyl, wood, stucco, etc.
•  Never run the vent downward as this may 
cause excessive temperatures which could 
cause a fire.
•  Vent  pipe  air  space  clearances  to  com-
bustibles are 1" on all sides except on the 
horizontal sections, which requires 2" clear-
ance from the top of the pipe. Where the 
termination cap penetrates a combustible 
wall, 1" air space clearance is required.
•  Have fireplace and selected vent compo-
nents on hand to help determine the exact 
measurements when elbowing or offsetting. 
Always use wall firestops when penetrating 
walls and firestops when penetrating ceil-
ings or attic spaces.
•  For installation of fireplace at elevations of 
4000 feet or greater, pay special attention 
to venting requirement recommendations.
 WARNING: Read all instruc-
tions completely and thoroughly 
before  attempting  installation. 
Failure to do so could result in 
serious injury, property damage 
or loss of life.
NOTICE: Failure to follow these in-
structions will void the warranty.