a) LED Lights and Audible Alarm Safeties
At startup, a 5-second delay occurs while the control board conducts an internal timer 
check. A beep occurs when the control switch is moved to the "ICE" position.
The red LED indicates proper control voltage and remains on unless a control voltage 
problem occurs. The green LEDs 1 through 4 energize and sequence from initial startup 
as listed in the table below. Note that the order of the LEDs from the outer edge of the 
control board is 1, 4, 3, 2. For details, see "II.B. Sequence of Operation."
Sequence Step
LED
Energized
Components
Time LEDs are On 
Min.
Max.
Avg.
1-Minute Fill Cycle
4
WV
1 minute
Harvest Cycle
1, 4, 2
Comp, FMR, WV, 
HGV 
2 minutes
20 minutes
3 to 5 minutes
Harvest Pump Timer 1, 3, 2
Comp, FMR, PM, 
HGV
0 seconds
50 seconds harvest pump timer 
setting
Freeze Cycle
1
Comp, FM/FMR, 
PM, LLV
5 minutes
freeze timer
setting
30 to 35 minutes
Pump-Out Cycle
1, 4*, 3, 2 Comp, FMR, WV*, 
PM, HGV 
10 seconds
20 seconds *pump-out timer 
setting
The built-in safeties shut down the unit and have alarms as listed below.
No. of Beeps 
(every 3 sec.)
Type of Alarm
Notes
1
High Evaporator Temp.  
(temperature > 127°F (53°C))
Check for harvest problem (stuck HGV or relay), hot 
water entering unit, stuck HM, or shorted thermistor. 
2
Harvest Backup Timer 
(harvest > 20 min. for two cycles 
in a row)
Check for open thermistor, HGV not opening, TXV or 
LLV leaking by, low charge, inefficient Comp., or WRV 
leaking by.
3
Freeze Timer 
(freeze > freeze timer setting for 
two cycles in a row)
Timer is factory set using S4 dip 
switch 9 & 10
Check for F/S stuck closed (up), WV leaking by, HGV 
leaking by, PM not pumping, TXV not feeding properly, 
LLV not opening, low charge, HM not bypassing, or 
inefficient Comp. 
To reset the above safeties, press the "ALARM RESET" button with the power supply on.
6
Low Voltage 
(92Vac±5% or less)
Red LED turns off if voltage protection operates.  
The control voltage safeties automatically reset when 
voltage is corrected.
7
High Voltage 
(147Vac±5% or more)
Legend: 
Comp–compressor; FM–fan motor; FMR–fan motor-remote; F/S–float switch; 
HGV–hot gas valve; HM–headmaster (C.P.R.); LLV–liquid line valve; PM–pump 
motor; 
TXV–thermostatic expansion valve; WRV–water regulating valve; WV–inlet 
water valve