c) Pump-Out Timer (S4 dip switch 3 & 4)
CAUTION
Do not adjust S4 dip switch 3 off and S4 dip switch 4 on for this model. 
Otherwise, pump motor does not rotate in the pump-out direction. 
When a pump-out is called for, the pump motor stops after the preceding freeze cycle. 
The pump motor restarts 2 seconds later in the reverse direction, taking water from the 
bottom of the tank and forcing pressure against the check valve seat allowing water to 
go through the check valve and down the drain. At the same time, water flows through 
the small tube to power flush the float switch. The pump motor drains the water tank for 
the time determined by the pump-out timer. The pump-out timer also acts in place of 
the harvest timer during cycles with a pump-out. The pump-out timer is factory set, and 
generally no adjustment is required. The pump-out timer control can be set to pump-out 
for 10 or 20 seconds.
S4 Dip Switch Setting Time (seconds)
Inlet 
Water 
Valve
No. 3
No. 4
T1
T2
OFF
OFF
10
150
closed
ON
OFF
10
180
closed
OFF
ON
10
120
open
ON
ON
20
180
closed
T1: Time to drain the water tank
T2: Harvest timer at pump-out
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump-out frequency control is factory set to drain the water tank every 10 cycles, 
and generally no adjustment is required. However, where water quality is bad and the 
icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The 
pump-out frequency control can be set to have a pump-out occur every cycle, or every 
2, 5, or 10 cycles. 
Timing of the first pump-out is dependent on S4 dip switch 5 & 6 settings. The first 
pump-out is factory set to occur after the 11th freeze cycle. See the table below.
S4 Dip Switch Setting
Pump-Out 
Frequency
1st Pump-Out
No. 5
No. 6
OFF
OFF
Every cycle
After 2nd freeze cycle
ON
OFF
Every 2 cycles
After 3rd freeze cycle
OFF
ON
Every 5 cycles
After 6th freeze cycle
ON
ON
Every 10 cycles
After 11th freeze cycle