Stardance Direct Vent - Rear Vent Gas Heaters 
20012950
2.  Locate the vent opening on the wall. Refer to Fig-
ures 18 & 19 to determine the top of the opening 
centerline. It may be necessary to first position the 
stove and measure to find the hole location. De-
pending on whether the wall is made of combustible 
materials, cut the opening to the size shown in Fig-
ure 18. Combustible wall openings must be framed 
as shown in Figure 18.
ST477
rear vent kit
6/00
27���"
(695mm)
to Top of 
Opening
CL
22���”
(565 mm)
Firestop
Ventilated Wall Plate 
- Open End Down
Finishing Collar
Seal 
Around 
Terminal
9³⁄₈” W x 10³⁄₈” H
Wall Opening
ST477
Wall Sleeve 
- Seal Around
Fig. 19  Rear Vent Kit 7TFSRSK installation.
VO584-100
Vent Opening
2/99   djt
9³⁄₈"
(240mm)
9³⁄₈"
(240mm)
7¹⁄₂"
(191mm)
VO584-100
Fig. 18  Locate vent opening.
Framing Detail
Vent Opening - Combustible Wall
Vent Opening -Noncombustible Wall
Venting System Assembly
General Information
The Stardance is approved for installation only with the 
vent components listed on Pages 12 & 13. Follow the 
vent component instructions exactly. 
For U.S. installations: The venting system must con-
form with local codes and/or the current National Fuel 
Gas Code, ANSI Z223.1/NFPA 54
For Canadian installations: The venting system must 
conform to the current CSA B149.1 installation code.
Rear Vent
Use Rear Vent Kit 7TFSRSK for an installation where 
the heater is parallel to the wall and the vent system 
extends straight back through that wall.
1.  Attach Inner Starter Pipe, (found in with the logset), 
to the stove.
  • 
Run a bead of sealant beneath the pipe bead and 
attach to the stove using three 1/4-20 x 3/8” phillips 
screws provided in the parts bag. (Fig. 17)
�����
������������
������������
����
Sealant
Phillips 
Screws
ST937
Fig. 17  Apply sealant to the starter pipe, and fasten to stove 
with Phillips screws.
ST347a
JUV
FK28 
rheostat install
9/21/00
Rheostat
Retaining Nut
Rheostat Knob
FK104
Fig. 16  Attach rheostat to bracket.
3.  Measure the wall thickness and cut the wall sleeve 
sections to proper length (MAXIMUM 12”). Assemble 
the sleeve with the #8 sheet metal screws supplied. 
Attach the firestop plate to the sleeve end with the 
holes. (Fig. 24) NOTE: The wall sleeve is required in 
combustible walls only.
4.  Install the Wall Firestop/Sleeve assembly into the 
wall cutout and fasten the firestop to the wall cutout 
framing members. (Figs. 19)
5.  Measure, and cut if necessary, the appropriate 
length of pipe section needed to make the connec-
tion through the wall.