Printronix l7032 참조 매뉴얼

다운로드
페이지 416
 212
Chapter
3
Bar Codes
Data Matrix Example
The following commands generated the Data Matrix bar codes shown below. 
In the command sequence, graphics mode data is 
italicized, and bar code 
data is boldface. See Chapter 2 for a detailed description of alphanumeric 
commands.
^PY^-^M01,01,010^KF^BNMXD8C36R12E200I5,0123456789^G^KF^-^PN^-
^PY^- enabled the graphics command sequence.
^M introduced the standard alphanumeric command.
The character height selected was 0.1 inches and character width was 
selected at 0.1 inches.
A 0.1 justification value plus 0 additional dots was selected for data 
placement.
^KF activated Dark Print.
^B introduced the bar code command.
N deselected printing the readable data field.
Letter M selected the Data Matrix bar code.
XD8 designates the x-dimension width of a single square module as 8 printer 
dots.
C36 sets the number of columns in the symbol at 36.
R12 sets the number of rows in the symbol at 12.
E200 sets the error correction level at ECC-200.
I5 set the format ID. This value is ignored with the ECC-200 error correction 
level set.
, (comma) separates the previous information from the data field.
0123456789 is the bar code data.
^G terminated the bar code command sequence.
^KF^- at the end of the bar code sequence turned off Dark Print.
^PN^- terminated the graphics mode.
^PY^-^M01,01,010^KF^BNM,0123456789^G^KF^-^PN^-
^M0101010^KF^IBARC,DATAMATRIX,XD8,C36,R12,E140,I5,N,A1B2C3D4E5F
6G7H8I9J0K12^G^
KF^-