Printronix l7032 참조 매뉴얼

다운로드
페이지 416
 214
Chapter
3
Bar Codes
Quiet Zone
Both ends of the bar code structure have blank quiet zones. The quiet zones 
should be at least 0.25 inches wide and completely blank to ensure accurate 
reading of the start/stop codes and to prevent adjacent bar codes from 
overlapping. You are responsible for providing sufficient space on the form for 
the quiet zones. A trailing quiet zone is provided automatically if an add-on 
code has been specified in the bar code command.
Start/Center/Stop Codes
The Start/Center/Stop codes are special character codes marking those 
portions of the bar code. These codes are automatically produced with each 
bar code.
Data Field
The bar code symbol uses a series of varying width bars and spaces to 
represent a limited numeric character set (numbers 0-9 and Special 
Characters Start, Center, and Stop). The bars and spaces vary in width from 1 
through 4 modules. Each character consists of 2 bars and 2 spaces that total 
7 modules. The symbol coding of the left data field is different from the right 
data field to permit read direction sensing.
Readable Data
The human readable data field provides a readable interpretation of the bar 
code data. Bar code data is printed below the horizontal bar code symbol, and 
to the left of a vertical bar code symbol.
Check Digit
The modulo-10 check digit is automatically calculated and inserted in the bar 
code symbol. The check digit provides the means to verify accurate scanning. 
EAN 8 Command Format
NOTE: See page 164 for the IBARC, command format and definitions.
Default Ratio:
(cc) 
dir p type data (cc)G
Variable Ratio:
(cc) 
dir p [9] [:] type [ratio] data (cc)G
(cc)
Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your VGL 
configuration.
dir
Represents the direction of the bar code. Enter B 
for horizontal bar codes; enter C for vertical bar 
codes.