8-22
Switching Commands
December 2004, 202-10010-02
Format
serial baudrate {1200 | 2400 | 4800 | 9600 | 19200 |
38400 | 57600 | 115200}
Mode
Line Config
no serial baudrate
This command sets the communication rate of the terminal interface to 9600.
Format
no serial baudrate
Mode
Line Config
serial timeout
This command specifies the maximum connect time (in minutes) without console activity. A value
of 0 indicates that a console can be connected indefinitely. The time range is 0 to 160.
of 0 indicates that a console can be connected indefinitely. The time range is 0 to 160.
Default
5
Format
serial timeout <0 - 160>
Mode
Line Config
no serial timeout
This command sets the maximum connect time (in minutes) without console activity to 5.
Format
no serial timeout
Mode
Line Config
set prompt
This command changes the name of the prompt. The length of name may be up to 64 alphanumeric
characters.
characters.
Format
set prompt <prompt string>
Mode
Privileged EXEC
show forwardingdb agetime
This command displays the timeout for address aging. In an IVL system, the [fdbid | all] parameter
is required. In an SVL system, the [fdbid | all] parameter is not used and will be ignored if entered.
is required. In an SVL system, the [fdbid | all] parameter is not used and will be ignored if entered.