Smart Switch Series Software Manual
Cabling Guidelines
D-3
 
Table-D-1.
Electrical Requirements of Category 5 Cable
Twisted Pair Cables
For two devices to communicate, the transmitter of each device must be connected to the receiver 
of the other device. The crossover function is usually implemented internally as part of the 
circuitry in the device. Computers and workstation adapter cards are usually media-dependent 
interface ports, called MDI or uplink ports. Most repeaters and switch ports are configured as 
media-dependent interfaces with built-in crossover ports, called MDI-X or normal ports.  Auto 
Uplink technology automatically senses which connection, MDI or MDI-X, is needed and makes 
the right connection.
 illustrates straight-through twisted pair cable.
Figure D-1:  Straight-Through Twisted-Pair Cable
SPECIFICATIONS
CATEGORY 5 CABLE REQUIREMENTS
Number of pairs
Four
Impedance
100  ± 15%
Mutual capacitance at 1 KHz
5.6 nF per 100 m
Maximum attenuation 
 
(dB per 100 m, at 20° C)
at 4 MHz: 8.2
at 31 MHz: 11.7
at 100 MHz: 22.0
NEXT loss (dB minimum)
at 16 MHz: 44
at 31 MHz: 39