Netgear GSM7224 사용자 설명서

다운로드
페이지 228
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 
8-66
Switching Commands
202-10009-01_060204
spanning-tree bpdumigrationcheck
This command enables BPDU migration check on a given interface. The all option enables BPDU 
migration check on all interfaces. 
Format  
spanning-tree bpdumigrationcheck {<slot/port> | all}
Mode  
Global Config
no spanning-tree bpdumigrationcheck
This command disables BPDU migration check on a given interface. The all option disables 
BPDU migration check on all interfaces. 
Format  
no spanning-tree bpdumigrationcheck {<slot/port> | 
all}
Mode  
Global Config
speed 
This command sets the speed and duplex setting for the interface. 
Format  
speed {{100 | 10} {half-duplex | full-duplex} | 1000 
full-duplex} 
Mode 
Interface Config
Acceptable values are:
100h  
100BASE-T half-duplex 
100f  
100BASE-T full duplex 
10h  
10BASE-T half duplex 
10f  
100BASE-T full duplex 
speed all
This command sets the speed and duplex setting for all interfaces. 
Format  
speed all {{100 | 10} {half-duplex | full-duplex} | 
1000 full-duplex}