4.  To ensure the gasket is sealed gently pull back on the 
Ethernet cable as shown in Figure 8.3 before mounting 
the enclosure to the wall or ceiling.
5.  Attach the enclosure to the wall or ceiling by tightening 
the four screws with sealing washers (Figure 8.4).  
 
NOTE: Be sure to use the supplied screws and  
sealing washers. Alternative washers will not seal  
the enclosure from moisture. Extra sealing  
washers are supplied.
Mounting to masonry or other durable surface wall,  
ceiling or overhang with cables routing along the wall  
or ceiling for side conduit installation.
1.  Position the supplied mounting template on the  
surface in the location where the camera will be installed.   
Trace and drill the mounting holes and the cable pass through hole as indicated. 
2.  Remove the conduit plug from the enclosure. Install a ½” (12.7mm) threaded 
conduit connector (not supplied) into the conduit hole on the enclosure. 
 
NOTE: To ensure proper weatherization on the conduit entry, properly seal 
the conduit threads with silicon.
3.  Pull the Ethernet cable through the conduit and then through the enclosure.  Pull 
enough cable through the conduit to attach an RJ-45 network connector, and to 
allow the network connector to plug into the Ethernet socket.
4.  Attach the enclosure to the wall or ceiling by tightening the four screws with 
sealing washers.   
 
NOTE: Be sure to use the supplied screws and sealing washers. Alternative 
washers will not seal the enclosure from moisture. Extra sealing washers  
are supplied. 
 
NOTE: When installing the Alliance-mx onto a ceiling tile, use hardware 
designed to secure the camera assembly to this surface, and ensure the ceiling 
tile material is secure. 
In addition, follow local regulations and laws that may have specific requirements 
governing the installation of security equipment on a ceiling tile surface.  IQinVision 
also strongly recommends the use of a ceiling tile brace and other mounting 
hardware designed to secure the Alliance-mx to the ceiling frame infrastructure.