Edge10 DAS401 사용자 가이드

다운로드
페이지 91
2.4  RAID VOLUME STATUS 
 
A RAID volume can be in any one of the following statuses. 
 
 
STATUS
 
 
MEANING
 
Good
 
All disks are currently functioning as normal.
 
 
Reduced
 
For RAID levels that provide data protection, one or more disks have failed but the data is 
still available via the RAID algorithms. The failed disk should be replaced as soon as 
possible to avoid loss of data.
 
 
Rebuilding
 
A failed disk drive has been replaced and the data is being regenerated on the replacement 
disk. When complete, the RAID Group will return to Good status.
 
 
Resynchronizing
 
An error has occurred and RAID algorithms be regenerated on this RAID Group. When 
complete, the RAID Group will return to Good status.
 
 
Failed
 
One or more disks have failed and RAID algorithms can no longer regenerate the data. The 
minimum number of failures required to reach this state depends on the RAID level: 
RAID 0, Concatenated, Contiguous: Single disk failure. 
RAID 1, 10, and 5: Two disk failure.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Ver.071015 
DAS401 User’s Manual 
 
10