Edge10 DAS401 사용자 가이드

다운로드
페이지 91
2.3 RAID 
LEVELS 
 
2.3.1      DISK STRIPING (RAID 0) 
 
Striping is a performance-oriented, non-redundant data mapping technique. While Striping is discussed as a 
 
RAID Group type, it is does not provide any fault tolerance. With modern SATA and ATA bus mastering 
 
technology, multiple I/O operations can be performed in parallel, enhancing data throughput. Striping arrays use 
multiple disks to form a larger virtual disk. The figure below illustrates a three-disk stripe set. Stripe one is written 
to disk one, stripe two to disk two, and so forth. RAID 0 sets can be comprised of two, three, or four drives. If the 
sizes of the disk segments are different, the smallest disk segment will limit the overall size of the RAID Group. 
 
Stripe0 
Stripe1 
Stripe2 
Stripe3 Stripe4 Stripe5
 
Stripe6
 
Stripe9
 
Stripe7
 
Stripe10
 
Stripe8
 
Stripe11
 
 
2.3.2      DISK MIRRORING (RAID 1) 
 
Disk mirroring creates an identical twin for a selected disk by having the data simultaneously written to two disks. 
This redundancy provides instantaneous protection from a single disk failure. If a read failure occurs on one drive, 
the system reads the data from the other drive.    RAID 1 sets are comprised of two drives, and a third drive can be 
allocated as a spare in case one of the drives in the set fails. If the sizes of the disk segments are different, the 
smallest disk segment will limit the overall size of the RAID Group. 
 
 
 
 
Block 0 
Block 1
 
Block 2
 
Block 3
 
Block 0 
Block 1
 
Block 2
 
Block 3
 
 
 
2.3.3      DISK MIRRORING AND STRIPING (RAID 10) 
 
RAID 10 combines the features of both RAID 0 and RAID 1. Performance is provided through the use of Striping 
 
(RAID 0), while adding the fault tolerance of Mirroring (RAID 1). The implementation of RAID 10 requires four 
drives. The drives are assigned as two sets of striped pairs. 
 
 
The data is written to RAID Group A, which is mirrored (RAID 1) and provides data redundancy. Alternating 
blocks of data are then striped across another RAID 1 mirrored set, shown as Set B in the figure above. This 
provides improved speed. 
Under certain circumstances, a RAID 10 set can sustain multiple simultaneous drive failures. 
 
 
 
Ver.071015 
DAS401 User’s Manual